Products

       At first from material and material supplier after a rigorous selection process, we choice all right         components for each items, we have advanced workshop, quality control system, specially custom         design engineers. OEM/ODM is welcome and can be done in donghua.
MODEL:HT-100 Triple Output Switching Power Supply

Features:
High efficiency,high reliability
Universal AC input /full range
100% full load burn-in test
Protections: Short circuit/ Over load / Over voltage
Cooling by free air convection
1 year warranty
Dimensions: 199*110*50mm (L*W*H)
Triple output high precision voltage



casing No. : H005

MODEL

HT-100C

HT-100D

CH1

CH2

CH3

CH1

CH2

CH3

OUTPUT

DC Voltage

5V

15V

-15V

5V

12V

24V

Voltage Tolerance

2%

6%

6%

2%

6%

6%

Rated Current

10A

2.5A

1A

6A

2A

2A

Current Range

2-12A

0.2-2.5A

0.1-1A

2-12A

0.1-2A

0.2-2A

Rated Power

100W

102W

Ripple & Noise

80mVp-p

150mVp-p

150mVp-p

80mVp-p

150mVp-p

150mVp-p

DC Adjustment Range

CH1+10,-5%

Setup, Rise, Hold Time

200ms,500ms,16ms

INPUT

Voltage Range

85132 VAC/170264VAC 4763 HzSelected by switch 240370VDC

AC Current

2.5A/115V 1.25A/ 230V

Efficiency

77%

79%

Inrush Current

Cold start 30A/115V 60A/230V

Leakage Current

0.5mA/240VAC

PROTECTION

Over Load

105%150%

Protection type: Shut down o/p voltage, re-power on to recover

Over voltage

CH1:115%135%

Protection: output shutdown re-power on to recover

ENVIRONMENT

Working Temp., Humidity

-10桫+50棻20%90 %RH

Storage Temp., Humidity

-20桫+85棻10%95 %RH

Vibration

10500Hz2G 10min./1cycle, period for 60min, each along X, Y, Z axes

SAFETY

Withstand Voltage

I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG: 500VDC/100M

STANDARD

Safety Standard

Design refer to UL1012

EMC Standard

Design refer to FCC PART15 J CONDUCTION CLASS B

OTHERS

Weight

0.83Kg

Packing

22pcs/18.6Kg/1.22CUFT

NOTE

1. All parameter measured in 230V input voltage, rated load 25, 70% humidity.
2. Tolerance: includes set up tolerance, line regulation and load regulation
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12twisted pair-wire terminated with a 0.1 &47
    parallel capacitor
4. The line regulation is measured at full load, input voltage from 85-264 VAC.
5. The load regulation is measured at 230VAC input voltage, and output current changed from mini load to fullload,other ouput is 60% rated load
6. Each output can within current range. But total output power cant exceed rated load