MODEL:HSP-500 Single Output Switching Power Supply

Features:
High efficiency,high reliability
Universal AC input /full range
100% full load burn-in test
Protection: Short circuit/Over load/Over voltage
Forced air cooling by built in DC fan
Built-in cooling Fan ON-OFF control
Fixed switching frequency at 110KHz
Built-in active PFC function, remote ON-OFF control, remote sense function
1 year warranty
Dimensions: 170*120*93mmL*W*H



casing No. : H009

MODEL

HSP-500
-12

HSP-500
-13.5

HSP-500
-15

HSP-500
-24

HSP-500
-27

HSP-500
-48

OUTPUT

DC Voltage

12V

13.5V

15V

24V

27V

48V

Voltage Tolerance

1%

1%

1%

1%

1%

1%

Rated Current

40A

36A

32A

20A

18A

10A

Current Range

0-40A

0-36A

0-32A

0-20A

0-18A

0-10A

Rated Power

480W

486W

480W

480W

486W

480W

Ripple & Noise

240mVp-p

240mVp-p

240mVp-p

240mVp-p

200mVp-p

300mVp-p

DC Adjustment Range

-16%,+10%

-12%,+15%

-10%,+20%

-16%,+10%

-12%,+11%

-15%,+16%

Setup, Rise, Hold Time

1.5s,50ms,20ms at full load

INPUT

Voltage Range

88264 VAC 4763 Hz124370VDC

Power Factor

PF>0.95/230VAC PF>0.95/115VAC at full load

AC Current

7A/115 V 3.5A/ 230 V

Efficiency

81%

82%

83%

85.5%

86.5%

87%

Inrush Current

18A/115V 36A/230V

Leakage Current

3.5mA/240VAC

PROTECTION

Over Load

105%135%

Protection type: Fold back current limiting, recovers automatically after fault condition is removed.

Over Voltage

115%135%

Protection type: Hiccup mode, recovers automatically after fault condition is removed

ENVIRONMENT

Working Temp., Humidity

-10桫+50棻20%90 %RH

Storage Temp., Humidity

-20桫+85棻10%95 %RH

Vibration

10500Hz2G 10min./1cycle, period for 60min, each along X, Y, Z axes

SAFETY

Withstand Voltage

I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC

STANDARD

Safety Standard

Design refer to UL1950,TUV EN60950

EMC Standard

Design refer to EN55022EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204

OTHERS

Weight

1.9Kg

Packing

10pcs/19.5kg/1.22CUFT

NOTE

1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12twisted pair-wire terminated with a 0.1 & 47 parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.