Products

       At first from material and material supplier after a rigorous selection process, we choice all right         components for each items, we have advanced workshop, quality control system, specially custom         design engineers. OEM/ODM is welcome and can be done in donghua.
MODEL:HS-60 Single Output Switching Power Supply

Features:
High efficiency,high reliability
Universal AC input /full range
100% full load burn-in test
Protection: Short circuit/Over load/Over voltage
Cooling by free air convection
Fixed switching frequency at 50KHz
1 year warranty
Dimensions: 159*97*38mm(L*W*H)



casing No. : H003

MODEL

HS-60-5

HS-60-12

HS-60-15

HS-60-24

HS-60-48

OUTPUT

DC Voltage

5V

12V

15V

24V

48V

Voltage Tolerance

2%

1%

1%

1%

1%

Rated Current

12A

5A

4A

2.5A

1.3A

Current Range

0-12A

0-5A

0-4A

0-2.5A

0-1.3A

Rated Power

60W

60W

60W

60W

62.4W

Ripple & Noise

120mVp-p

120mVp-p

150mVp-p

150mVp-p

200mVp-p

DC Adjustment Range

+10, -5%

10%

10%

10%

10%

Setup, Rise, Hold Time

800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC

INPUT

Voltage Range

85264 VAC 4763 Hz120370VDC

AC Current

2A/115 V 1A/ 230 V

Efficiency

73%

76%

77%

79%

79%

Inrush Current

Cold start 30A/115VAC 60A/230VAC

Leakage Current

3.5 mA/240VAC

PROTECTION

Over Load

115%165%

Protection: Shut down o/p voltage, re-power on to recover

Over voltage

115%135%

Protection: Hiccup mode, recovers automatically after fault condition is removed

ENVIRONMENT

Working Temp., Humidity

-10桫+60棻20%90 %RH

Storage Temp., Humidity

-20桫+85棻10%95 %RH

Vibration

10500Hz2G 10min./1cycle, period for 60min, each along X, Y, Z axes

SAFETY

Withstand Voltage

I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC

STANDARD

Safety Standard

Design refer to UL1012, UL1950TUV EN60950

EMC Standard

Design refer to EN55022EN61000-3-2-3EN61000-4-23456811ENV50204EN55024

OTHERS

Weight

0.51Kg

Packing

30pcs/15.8Kg/0.99CUFT

NOTE

1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12twisted pair-wire terminated with a 0.1 & 47 parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.