MODEL:HS-25 Single Output Switching Power Supply

Features:
High efficiency,high reliability
Universal AC input /full range
100% full load burn-in test
Protection: Short circuit/Over load/Over voltage
Fixed switching frequency at 56KHz
Cooling by free air convection
1 year warranty (UL Cerfiticate)
Dimensions: 99*97*36mm(L*W*H)



casing No. : H001

MODEL

HS-25-5

HS-25-12

HS-25-15

HS-25-24

OUTPUT

DC Voltage

5V

12V

15V

24V

Voltage Tolerance

2%

1%

1%

1%

Rated Current

5A

2.1A

1.7A

1.1A

Current Range

0-5A

0-2.1A

0-1.7A

0-1.1A

Rated Power

25W

25.2W

25.5W

26.4W

Ripple & Noise

50mVp-p

100mVp-p

100mVp-p

100mVp-p

DC Adjustment Range

+10,-5%

10%

10%

10%

Setup, Rise, Hold Time

800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC at full load

INPUT

Voltage Range

85264 VAC 47 63 Hz120370VDC

AC Current

0.6 A/115 V 0.35A/ 230 V

Efficiency

72%/115VAC

76%/115VAC

77%/115VAC

80%/115VAC

Inrush Current

Cold start 15A/115V 30A/230V

Leakage Current

0.75 mA/240VAC

PROTECTION

Over Load

110%160%

Protection: Shut down o/p voltage, re-power on to recover

Over Voltage

115%135%

Protection: Hiccup mode, recovers automatically after fault condition is removed

ENVIRONMENT

Working Temp., Humidity

-10桫+60棻20%90 %RH

Storage Temp., Humidity

-20桫+85棻10%95 %RH

Vibration

10500Hz2G 10min./1cycle, period for 60min, each along X, Y, Z axes

SAFETY

Withstand Voltage

I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC

STANDARD

Safety Standard

Design refer to UL1012, TUV EN60950

EMC Standard

Design refer to EN55022EN61000-3-2-3EN61000-4-2345ENV50204EN55024

OTHERS

Weight

0.28Kg

Packing

45pcs/13.2Kg/0.99CUFT

NOTE

1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12twisted pair-wire terminated with a 0.1 & 47 parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.