Products

       At first from material and material supplier after a rigorous selection process, we choice all right         components for each items, we have advanced workshop, quality control system, specially custom         design engineers. OEM/ODM is welcome and can be done in donghua.
MODEL:HS-100R Single Output Switching Power Supply

Features:
High efficiency,high reliability, water proof
AC input range selected by switch
100% full load burn-in test
PROTECTION:Short circuit/Over load/Over voltage
Forced air cooling by built in DC fan
Built-in cooling Fan ON-OFF control
Fixed switching frequency at 66KHz
1 year warranty
Dimensions: 198144111mm(L*W*H)



casing No. : FY-02
MODEL
HS-100R-5
HS-100R-12
HS-100R-15
HS-100R-24

OUTPUT

DC Voltage

5V

12V

15V

24V

Voltage Tolerance

1%

1%

1%

1%

Rated Current

20A

8.5A

6.7A

4.2A

Current Range

0-20A

0-8.5A

0-6.7A

0-4.2A

Rated Power

100W

102W

100.5W

100.8W

Ripple & Noise

80mVp-p

100mVp-p

100mVp-p

100mVp-p

DC Adjustment Range

10%

10%

10%

10%

Setup, Rise, Hold Time

300ms,150ms,20ms

INPUT

Voltage Range

90132VAC/180264 VAC 47~63Hz

AC Current

2.4A/115VAC  1.2A/230VAC

Efficiency

80%

83%

84%

86%

Inrush Current

Cold start 40A/230V

Leakage Current

2mA/240VAC

PROTECTION

Over Load

110%150%

Protection:Hiccup mode, recovers automatically after fault condition is removed

Over Voltage(V)

5.75~6.75V
13.8~16.2V
17.25~20.25V
27.6~32.4V

115%~135% Protection: Shut down o/p voltage, re-power on to recover

ENVIRONMENT

Working Temp., Humidity

-10桫+60, 20%90 %RH

Storage Temp., Humidity

-20桫+85, 10%95 %RH

Vibration

10500Hz2G 10min./1cycle, period for 60min, each along X, Y, Z axes

SAFETY

Withstand Voltage

I/P-O/P: 3KVAC I/P-FG 1.5KVAC O/P-FG: 0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC

STANDARD

Safety Standard

Design refer to UL1012, EN60950

EMC Standard Design refer to EN55022EN55024EN61000, IEC801-2,3,4, IEC555-2

OTHERS

Weight

0.77kg

Packing

12pcs/10.24kg/2.5CUFT

NOTE

1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12twisted pair-wire terminated with a 0.1 & 47 parallel capacitor.

3.Tolerance: includes set up tolerance, line regulation and load regulation.

4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.