Products

       At first from material and material supplier after a rigorous selection process, we choice all right         components for each items, we have advanced workshop, quality control system, specially custom         design engineers. OEM/ODM is welcome and can be done in donghua.
MODEL:HPSPL-100 Single Output Switching Power Supply
Features
Universal AC input/ full range
Built-in active PFC function
Protections: Short circuit
Cooling by free air convection
100% at full load aging-test
Fixed switching frequency at PFC67KHzPWM134KHz
1 year warranty
Dimensions222*62*32mm(L*W*H)

MODEL

HPSPL-100-3.3 HPSPL-100-5 HPSPL-100-7.5 HPSPL-100-12 HPSPL-100-13.5 HPSPL-100-15 HPSPL-100-24 HPSPL-100-27 HPSPL-100-48
OUTPUT DC Voltage 3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V
Rated Current 20A 20A 13.5A 8.5A 7.5A 6.7A 4.2A 3.8A 2.1A
Current Range 020A 020A 013.5A 08.5A 07.5A 06.7A 04.2A 03.8A 02.1A
Rated Power 66W 100W 101.25W 102W 101.25W 100.5W 100.8W 102.6W 100.8W
Ripple & Noise 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p
DC Adjustment Range 3.143.63V 4.755.5V 7.138.25V 11.413.2V 12.814.9V 14.316.5V 22.826.4V 25.729.7V 45.652.8V
Voltage Tolerance 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 1.0% 1.0% 1.0%
Line adjusting rate 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
Load adjusting rate 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
Setup, Rise Time 600ms/230VAC           1200m,30ms/115VAC (at full load)
Hold Time(Typ.) 28ms/230VAC           28ms/115VAC ( at full load)
INPUT Voltage Range 85264VAC  or   120370VDC
Frequency 4763Hz
PFC 0PF>0.95/230VAC       PF>0.98/115VAC ( at full load )
Efficiency(Typ.) 69% 75% 76% 79% 79% 80% 83% 83% 83%
Current Range(Typ.) 1.7A/115VAC       0.75A/230VAC
Inrush Current (Typ.) Cold start 30A/230VAC
Leakage Current <2mA/240VAC
PROTECTION Over Load Rated OUTPUT105150%
Protection typecurrent limiting,recovers automatically after fault condition is removed.
Over voltage 3.84.45V 5.756.75V 8.610.1V 13.816.2V 15.518.2V 17.2520.25V 27.632.4V 3136.45V 55.264.8V
Protection typeshut down OUTPUT voltagere-power on to recover.
ENVIRONMENT Working Temp -10+60 (see load derating curve)
Working Humidity 2090% no cooling
Storage Temp., Humidity -20+85, 10 95% RH
Temp. range 0.05%/ (050)
Vibration 10500Hz2G 10min./1cycle, period for 60min, each along X, Y, Z axes
Safety & EMC Safety Standards Design refer to UL60950-1,TUV EN60950-1
Withstand Voltage I/P-O/P:3KVAC      I/P-FG:1.5KVAC     O/P-FG:0.5KVAC
Isolation Resisitance I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC
EMC Design refer to EN55022 (CISPR22) Class B
Harmonic Current Design refer to EN61000-3-2,-3
ESA Design refer to EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024, heavy industrial class-A standard.
OTHERS Weight 0.51kg
Packing 24pcs/13.9kg/1.76CUFT
NOTE 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12twisted pair-wire terminated with a 0.1 & 47 parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered as a component inside the equipment, the final equipment must be confirmed it meets EMC directives.
5.It should derating the output at low input voltage condition, see the derating curve in details.