Products

       At first from material and material supplier after a rigorous selection process, we choice all right         components for each items, we have advanced workshop, quality control system, specially custom         design engineers. OEM/ODM is welcome and can be done in donghua.
MODEL:HPSP-1000 With PFC and Parallel Function Switching Power Supply

Features:
 High efficiency, high reliability
 Universal AC input/ full range
 Built-in active PFC function, PF>0.95
 Protections: Short ciruit/ Over load /Over voltage/Over    temperature
 Built-in constant current limiting circuit
 Forced air cooling by built-in DC fan
 Current sharing up to 2 units or 2000W
 Built-in remote ON-OFF control and remote sense   function
 Built-in active current sharing and parallel function
 1 year warranty
 Dimensions: 278*129*127mm L*W*H



casing No. : H030

MODEL

HPSP-1000
-5

HPSP-1000
-12

HPSP-1000
-13.5

HPSP-1000-15 HPSP-1000-24 HPSP-1000-27 HPSP-1000-48

OUTPUT

DC Voltage

5V

12V

13.5V

15V

24V

27V

48V

Voltage Tolerance

6.0%

3.0%

2.0%

2.0%

1.0%

1.0%

1.0%

Rated Current

145A

75A

67A

60A

37.6A

33.6A

19A

Current Range

0-145A

0-75A

0-67A

0-60A

0-37.6A

0-33.6A

0-19A

Rated Power

725W

900W

904.5W

900W

902.4W

907.2W

912W

Peak Value Power

800W

1000W

1000W

1000W

1000W

1000W

1000W

Ripple & Noise

100mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

200mVp-p

DC Adjustment Range

-5%, +10%

-17%, +10%

11%

-10%+20%

-17%,+10%

11%

-15%,+17%

Setup, Rise, Hold Time

1.5s,50ms,24ms/230VAC 1.5s,50ms,24ms/115VAC at full load

INPUT

Voltage Range

90264 VAC 47-63Hz127370VDC

Power Factor

PF>0.95/230VAC PF>0.95/115VAC at full load

AC Current

14A/115 VAC 7A/230VAC

Efficiency

77%

84%

84%

84%

86%

86%

86%

Inrush Current

Cold start 40A/115VAC 70A/230VAC

Leakage Current

<2mA/240VAC

PROTECTION

Over Load

115%~140%

Protection: Constant current limiting, recovers automatically after fault condition is removed

Over Voltage

115%135%

Protection type: Shut down o/p voltage, re-power on to recover

Over Temp

95 (TSW1) Detect on the heatsink of PFC MOSFET 90 (TSW2) Detect the winding of output choke

Protection:Shut down o/p voltage, recovers automatically after temperature goes down

FUNCTION

Remote Control

RC+/RC:4 ~ 10VDC Power off, <0 ~ 0.8VDC Power on

ENVIRONMENT

Working Temp., Humidity

-10桫+65棻20%90 %RH

Storage Temp., Humidity

-20桫+85棻10%95 %RH

Vibration

10500Hz2G 10min./1cycle, period for 60min, each along X, Y, Z axes

SAFETY

Withstand Voltage

I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC

STANDARD

Safety Standard

Design refer to UL1950,TUV EN60950

EMC Standard

Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024

OTHERS

Weight

5.2Kg

Packing

3pcs/16.3Kg/1.42 CUFT

NOTE

1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12twisted pair-wire terminated with a 0.1 &47
   parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.10% Duty cycle maximum within every 30 seconds(max.). Average output power should not exceed the rated power.
5.The power supply is considered a component which will be installed into a final equipment. The final equipment must
   be re-confirmed that it still meets EMC directives.