Products

       At first from material and material supplier after a rigorous selection process, we choice all right         components for each items, we have advanced workshop, quality control system, specially custom         design engineers. OEM/ODM is welcome and can be done in donghua.
MODEL:HDR-30 Single Output Industrial DIN Rail Power Supply
”¤Universal AC input/ full range
”¤Protections: Short circuit/ Over load/ Over voltage
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Isolation class¢ņ
LED indicator for power on
100% full load burn-in test
1 year warranty
Dimensions: 78*93*56mm (W*H*D)


casing No. : H033

MODEL

HDR-30-5

HDR-30-12

HDR-30-15

HDR-30-24

OUTPUT

DC Voltage

5V

12V

15V

24V

Voltage Tolerance

”Ą2%

”Ą1%

”Ą1%

”Ą1%

Rated Current

3A

2A

2A

1.5A

Current Range

0-3A

0-2A

0-2A

0-1.5A

Rated Power

15W

24W

30W

36W

Ripple & Noise

80mVp-p

120mVp-p

120mVp-p

150mVp-p

DC Adjustment Range

-5%,+10%

”Ą10%

”Ą10%

”Ą10%

Setup, Rise, Hold Time

100ms,30ms/230VAC100ms,30ms/115VAC at full load

INPUT

Voltage Range

85”«264 VAC47”«63 Hz; 120”«370VDC

AC Current

0.88 A/115 V 0.48A/ 230 V

Efficiency

74%

81%

82%

83%

Inrush Current

Cold start 15A/115V 30A/230V

PROTECTION

Over Load

105%”«160%

Protection type: Constant current limiting, recovers automatically after fault condition is removed

Over Voltage

115%~135%

Protection type: Shut down o/p voltage, re-power on to recover

ENVIRONMENT

Working Temp., Humidity

-20”ꔫ+60”ę£»20%”«90 %RH

Storage Temp., Humidity

-40”ꔫ+85”ę£»10%”«95 %RH

Vibration

10”«500Hz£¬2G 10min/1cycle, period for 60min, each along X, Y, Z axes

SAFETY

Withstand Voltage

I/P-O/P:3KVAC

Isolation Resistance

I/P-O/P:100M Ohms / 500VDC

STANDARD

Safety Standard

Design refer to UL60950-1,TUV EN60950-1,EN50178

EMC Standard

Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2,EN61204-3

OTHERS

Weight

0.27Kg

Packing

48pcs/14Kg/1.02CUFT

NOTE

1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25”ę of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12”åtwisted pair-wire terminated with a 0.1¦Ģ & 47¦Ģ parallel capacitor.

3.Tolerance: includes set up tolerance, line regulation and load regulation.

4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.