Products

       At first from material and material supplier after a rigorous selection process, we choice all right         components for each items, we have advanced workshop, quality control system, specially custom         design engineers. OEM/ODM is welcome and can be done in donghua.
MODEL:HDC-35 Single Output Switching Power Supply
Features:
Universal AC input/ full range
Protection: Short circuit/Over load/Over voltage
Cooling by free air convection 100% full load burn-in test
1 year warranty
Dimensions: 99*97*36mm(L*W*H )


casing No. : H001

MODEL

HDC-35A

HDC-35B

OUTPUT

OUTPUT

CH1

CH2

CH1

CH2

DC Voltage

5V

12V

5V

24V

Rated Current

4A

1A

2.2A

1A

Current Range

0.5-5A

0.1-1.5A

0.5-4A

0.2-1.3A

Rated Power

32W

35W

Ripple & Noise

80mVp-p

120mVp-p

80mVp-p

200mVp-p

DC Adjustment Range

CH14.75-5.5V

CH1:4.75-5.5V

Voltage Tolerance

2.0%

6.0%

2.0%

6.0%

Line Regulation

0.5%

1.0%

0.5%

1.0%

Load Stability

1.5%

3.0%

1.5%

3.0%

Setup, Rise, Hold Time

500ms30ms/230VAC 1200ms30ms/115VAC
50ms/230VAC, 10ms/115VAC

INPUT

Voltage Range

AC 85264VAC DC120370VDC

Frequency

47-63Hz

Efficiency

78%

81%

AC Current

0.75A/ 115V 0.5A/230V

Inrush Current

Cold start 45A/230VAC

Leakage Current

< 2mA/240VAC

PROTECTION

Over Load

110%150% Protection: Hiccup moderecovers automatically after fault condition is removed

Over voltage

CH15.75-6.75 Protection type: Shut down o/p voltage, re-power on to recover

ENVIRONMENT

Working Temp., Humidity

-20桫+60棻20%90 %RH no cooling(Refer to output load derating curve)

Storage Temp., Humidity

-40桫+85棻10%95 %RH

Vibration

10500Hz2G 10min./1cycle, period for 60min, each along X, Y, Z axes

SAFETY

Withstand Voltage

I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC

STANDARD

Safety Standard

Design refer to UL60950-1,CBIEC60950-1

EMC Standard

Design refer to EN55022 CLASSB EN61000-3-2-3 EN61000-4-23456811ENV50204EN55024EN61000-6-1

OTHERS

Weight

0.36Kg

Packing

45pcs/17Kg/0.99CUFT

NOTE

1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12twisted pair-wire terminated with a 0.1 & 47 parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.Each output can reach to maxium current, but the total load can not exceed rated power.
5.The power supply is considered as a component inside the equipment, the final equipment must be confirmed it meets EMC directives.